Time Limit/Maintenance Check

  TTP B1-L1 ATA05 Beech 90 Series B2-L1 Time Limit/ Maintenance Check Inspection Requirements (1) 200-Hour Phase inspection program -  A complete inspection is 800 hours or 24 months, w hich e v er occurs first. The inspection c ycle is d i vided into four phases and each inspection c ycle is accomplished at 200 hours.  Section 5-10-01 . (2) Alternate Phase inspection program   F or operators f l ying less than 400 hours b ut more than 200 hours in 24 months.   P erfo r m scheduled phase inspections 1 and  2 t o gether within 12 months after the last  inspection.   P erfo r m scheduled phase inspections 3 and  4 t o gether within 12 months after complet - ing the phase 1 and 2 inspections.  Section 5-20-00. (3) Biennial inspection program   F or operators f l ying less than 200 hours in 24 months. ...